•QUICK SCAN SURVEY
PART C: INVENTORY EXISTING ICT INFRASTRUCTURE

Developing Information and Communication Technology (ICT) services for institutes of higher education and research.

QUESTIONNAIRE

January 2000

General Information

Universidad Nacional de Ingeniería, UNI

1. Description of existing networking facilities

1.1 Inter-campus networking

Describe in brief inter-campus networking facilities (if any) by specifying data communication links between campuses (or university’s main compound) and individual buildings outside the campuses (or main compound). Please specify for each link the points (buildings) connected by the link, the distance the link is bridging, the technology used and the capacity of the link.

If possible, include a schematic drawing!

There is no inter-campus Net at the moment.

At the present time exist certain sectors of the University of the Recinto Simón Bolívar that don't have connectivity, but in a future we pretend to connect them through wireless communication, for example: IES, Graduate degree UNI and others. We pretend to make the wireless connection among the two Campus that belong to the National University of Engineering.

1.2 Campus networks

Describe in brief the networks available (if any) at the various campuses facilities providing data communication connectivity to the individual buildings. Do not include the description of LANs at the individual buildings! Please specify buildings connected, distances, the technology used and capacities. If possible, include a schematic drawing!

The Nets of the two Campus of the National University of Engineering are described in the point 1 that makes reference to the Description of the Existent Services of Net and the diagrams of this services are included in the Annex B.

The University Camp “Simón Bolívar” has a Center of Central Computation, located in the Building 03 belonging to Faculty of Electrical and Computer Engineering (FEC), this consists of 03 plants (Lower plant (Basement), first Floor and second Floor).

In the lowest Plant (Center of Computation)

Inside Center of Computation exists two HUB , one that controls the internal equipment inside it and the second HUB is the one that serves as connection among the different switch that are located along the enclosure. The speed of connection of this main switch is for some lines

of 10/10 and for the main lines of conection of 10/100.

First Floor:The Laboratories of Computation Leyda Montenegro and Main Laboratory are located", with a total capacity of 46 computers.

These laboratories have a direct connection through a HUB Switch of the Center of Computation with a connection of 100 Mbps.

Laboratory Leyda Montenegro:30 Intel Pentium MMX, connection of 10Mbps.

Main laboratory :16 Intel Pentium II, connect of 100 Mbps.

The HUB mentioned above is linked to another Switch of 100 Mbps, to feed the following offices: Radio Shack, Tecnosoluciones and Departure of Postgrado FEC.

Starting from the second switch that is connected with the main switch the connection is carried out to 10 Mbps and it feeds the Superior Administrator Manager that is composed by Parsonage, Academic Vice Parsonage, Parsonage Vice General,Department of Investigation and General Secretary. Of all these dependences connection only exists in Academic Vice Parsonage, Vice Parsonage of Investigation and Development and General Secretary. The second switch also feeds the Building 03 of the Faculty of Electrical and Computer Engineering (FEC) that is composed by all the Departments of Computation, Vice Decanatura and Careers of Special Modality.

Of the second switch another switch is connected with a connection of 100 Mbps, which feeds the Cyber Club that has 18 PC's and the whole physical plant of the first floor and second floor of Faculty of Electrical and Computer Engineering (FEC), besides feeding to the Laboratory of the Faculty of Chemical Engineering that has 15 PC's and the connection is carried out to a speed of 10 Mbps.

Lastly, we have a central repeater that transfers information to a speed of 100 Mbps and which connect the following departments: Department of Communications, Department of Electronic, Department of Electric, Laboratory of Simulation in which exists a small LANS that has 23 connected stations, Academic Secretary of the Faculty of Electrical and Computer Engineering (FEC), with 4 PC's and a PC's with connection NT exists.

In the Campus Simón Bolívar some instances exist like: Registration Central Academic, PIDMA, human resources, Department of Graduate degree, Programs of Urban and Territorial Environmental Studies that are not still connected, but some have communication with Supplies of Services outside of the such University as: Telematix, Alfanumeric, IBW, etc.

The information with respect to the University Campus Pedro Araúz Palacios is described in the figure A that is attached to this form. It is necessary to highlight that the way in that it is described in supposition form is for the fact that still we continue working in the establishment of the physical conectivity, because in this campus the ITC is relatively new and this is in amplification process in the whole campus. However, that described in the annex is taking to cavality point for point. In such way that what already exists wired and connected it fulfills the specifications described in such annex.

> Up

First level connectivity map for "Simon Bolivar" Campus... see or dowload

Second and Third level connectivity map for "Simon Bolivar" Campus... see or download

1.3 LANs at the individual buildings

In the University Enclosure Simón Bolívar the Lans is distributed in the following way:

Faculty of Electrical and Computer Engineering (FEC) there are some conection of 10 Mbps and another one of 100 Mbps, with UTP Rj45, Category 5, with an approximate capacity of 168 PC connected to Internet and an approximate of 200 Electronic equipment connected to this local net.

Laboratory of Simulation - FEC: Here, we have a LAN with a Server Celeron of 300 MHZ of speed that connects 22 workstations using Windows NT.

Academic Registration -FEC: there are a server with the following especification, Pentium II that connects 2 PC's Intel Pentium of 233 MHZ with Windows 95 '.

Chemistry Faculty: There are a local net with 6 computer Macinton with operating system Mac OS through Internet , the physical means of communication is UTP Rj45 Category 5.

Central registration: Exist a Server Intel Inside Celeron with Windows NT and it connects to 3 workstations through a Hub of 8 Ports of 10/10.

In the University Enclosure Pedro Araúz the Lans is described in the following way:

Faculty of Sciences and Systems: A server Windows NT, Intel Pentium of 600 MHZ connect to a Central Switch that is linked using Optic Fiber with a Switch located in the Laboratory of Sciences and Systems that uses internaly Rj45 Category 5 and it connects using Windows NT all the computer inside. This same switch has wireless connection with CNEG, Academic Secretary F.C and S. and Graduate degree and it connects 8 computers which communicate among them with Rj45 Category 5, besides possessing connection UTP Rj45 with Parsonage, Administration, the different departments of the Faculty of Sciences and Systems as: Department of Social, Department of Languages, Department of Mathematical and Department of Physics. Also we are carrying out the one wired structure to be able to connect to all the departments and Laboratories of the faculty of Construction and Faculty of Technology of the Industry. We have a server Linux that has connection with 27 computers of the Laboratory of Systems.

Academic Secretary –Construction’s Faculty: Here, we have a lan that has a Server Intel pentium of 450 MHZ,it connects through a Hub of 16 Ports from 10/10 to 4 computer with which is carried out the transfer of the Automatic System of Registration designed in Visual Basic 5.0 with connection to Access 97 '.

We used as a mean of transmission UTP Rj45 Category 5.

Multimedia Center –Industrial Technology Faculty : there are a lan with a Server Intel Pentium of 450 MHZ that connects through a HUB of 16 Ports from 10/10 to 12 computers AT&T 486. Means of Transmission RJ45 Category 5.

> Up
1.4 Connection to Internet/e-mail

University enclosure Simón Bolívar"

Center of Communications located in the Basement belonging to the Faculty of Electrical and Computer Engineering (FEC): It is connected to 64 Kbps with Telematic and it offers service to 168 workstations.

PIDMA: 1 connection with Telematic.

Department of Graduate degree: It is connected the Nodo Nicarao and IBW.

Program of Urban and Territorial Environmental Studies belonging to the Faculty of Architecture has a connection with Alfanumeric to 28.8 Kbps.

Central library RUSB:It has conection with IBW to 36.6 Kbps

Chemistry Faculty : It has conection with IBW to 36.6 Kbps

Tecnosoluciones: It has conection with telematic.

University enclosure “Pedro Araúz"

Center of Communications located in the high plant of the Main Building of the Enclosure belonging to the Faculty of Sciences and Systems: It is connected to 64 Kbps with DATATEX using like means of Transmission wireless communication of Packed Radio and at the moment it offers service to 68 workstations.

Other such dependences as: Decanatura, Academic Registration, Department of Roads of Transport of the Construction’s Faculty has conection with IBW through it lines phone to 36.6 Kbps. In a same way in the Faculty of Technology of the Industry the decanato has its conection with IBW using it lines phone.

1.5 Internet/e-mail facilities for common use

Does he/she have the university the central service of Internet/e-mail for different abilities, departments, etc? if the answer is if, please specify the configuration of the service, the localization of the services and the name of the groups responsible for its operation and maintenance shortly.

University Campus ” Pedro Araúz P."

In this Campus the services of Internet are given by the Center of Communications that is in the Main Building especifically in Highest Plant.

This center of communications is in charge of the maintenance and operability of the whole net in the Campus and of offering the services of Internet and E-mail. The current configuration consists on a proxy server in which there are connected 68 workstations at the moment. However,we continue carrying out the one wired corresponding to connect bigger quantity of dependences. This proxy runs low Windows NT and the connection with DATATEX it is a Wireless form from Packed Radio to 64 Kbps. This Proxy is connected to a Bank of Modems of 32 Ports. The connection of this proxy with some entities is carried out through Optic Fiber that is connected Switch Hub of 32 Ports.

University Campus “Simón Bolívar"

In this enclosure the services of Internet are given by the Center of Computations that is in the Main Building, Basement. This center of computations this in charge of the maintenance and operability of the whole Net in the campus and of offering the services of Internet and E-mail. The current configuration consists on a proxy server and a Servant of Domains in which there are connected 168 workstations at the moment. This runs low Unix and the connection with TELEMATIC is Wireless form from Packed Radio to 64 Kbps. This Proxy is connected to several switch/hub that serve as repeaters using UTP RJ45 Category 5.

> Up

2. Other ICT resources

2.1 Describe briefly the major computerized information systems in use at your university. Please indicate the number (estimate) of end-users for each particular administration and if possible, the department considered the main user.

University Campus “Pedro Arauz P."

In our campus we have 3 Faculties : Construction’s Faculty, Technology of the Industry Faculty and Faculty of Sciences and Systems, as well as administration.

In each Academic Secretaries of each Faculties there are an automatic Registration system , which are described next.

Construction’s Faculty: System designed in Visual Basic Enterprise Edition and connected to Access 97 '.

Technology of the Industry Faculty : System designed in Visual Fox Pro

Faculty of Sciences and Systems: System designed in Access 97 '.

University Campus “Simón Bolívar"

Automatic system of Registration that is been made using Informix, we are thinking to make an unique countable system that it is not still finished. There are a system of Payroll in human resources elaborated in Sybase although at the moment the one that is used is one that was designed in Access 97 '.

Academic secretary of Chemistry: A system of academic control is taken, it was developed in Clipper where it is controlled the registration, general records, records of qualifications and several listings. The quantity of users belongs to 2 people. This system is thinking to be improve.

Academic secretary of the Architecture’s Faculty :The system of automatic registration has not been concluded and it is developing in Access 97 ', in this system they are goint to register some processes of registration, for example, the student's inscription and registration of notes, it is not goint to take in count the previous and precedences , that system is going to run in a single computer. This Faculty have a population of 500-550 students .

Academic secretary FEC: System developed in Linux and Informix in 4PC's. Used by 4 users, 1 administrator and 3 operators. Total of students 1400. 500 in Computation Science, 400 in Electric and 600 in Electronics Engeenier.

PIDMA:System of Accounting. 2 people and only one computer. They also have the system of hydrological modelation using Nike 11.(3 People use it)

System of Modelation Underground Waters FLOWPATH approximately among 8 to 10 people use it. (it is not continuous).

Library: Micro CD-EASIES where databases are managed of lend of books, statistical, inventories of books and others.

Totally concluded, for the Administration of this software 2 exist you scheme and a single user is the one that administers it.

Human resources: System of Schedule of the National University of Engineering of the two campus is managed, with a population of approximately 800 workers, this system is complete, they don't have conectivity using net, although there are the finantial area without conection. Approximate of computers: 12 computers.

2.2 What is the number of PC’s in use within the administration (estimate):

In the “ Pedro Araúz” campus, the finantial area uses three computers, which two of them are 586 with 233 MHZ of Speed, 32MB of Memory and Hard Disks with capacity of 2.2GB, and the other one is 486 with 166 MHZ of Speed, 8MB of Memory and Hard Disk of 600MB.

In the “ Simón Bolivar” campus, the finantial area uses two computers.

 

> Up

2.3 What is the number of PC’s in use at the central library (estimate):

In the “ Pedro Araúz” campus, main library have 23 computers with the following characterists:

20 computer Intel pentium II with 450 MHZ of Speed, 32 MB of Memory and Hard Disks of 4.3 GB.

1 computer Pentium II with 450 MHZ of Speed, 64 MB of Memory and SCSI Hard Disk of 9.3 GB.

1 Computer 586 with 300 MHZ of Speed, 32 MB of Memory and Hard Disk of 4.3 GB.

1 Computer 486 with 166 MHZ of Speed, 16 MB of Memory and Hard Disk of 1.2 GB.

In the “ Simón Bolivar” campus , main library have 7 computers in use and they are trying to get 11 more with the finantial support of the project SAREC.

2.4 What is the number of PC’s in use at for education and research (estimate):

If possible, give estimates for each faculty, institute, school, other.

The information of the Pedro Arauz campus is described detailed in the annex C.

2.5 Please indicate the average condition of the present available PC’s.

In the pedro Arauz campus there are around of 50% of the total computers with a lifetime of 3 years ago and the other 50% are most actually, for example, 686 or Pentium II with 450 MHZ, and they have at least 32 MB of Memory and Hard Disks of 4.3 GB. Its lifetime is around one years ago.

In the Simón Bolivar Campus there are around 80% of old computers and the other 20% was recently acquired.

2.6 Please describe in brief the condition of the electricity supply system at your university:

Actually, there are 6 transformer station that are identified as:

T1: This one has a capacity of 3*50 Kva.

Places that it feed: Library, Bookstore, House of keepers, Bar UNI and the classroom building 5, 6, 7, 8, 9, and UNEN. This one is working with 70% of Nominal Charge.

T2: This one has a capacity of 3*100 Kva.

Places that it feed: Arquitectural building (3 plants); building number 02(2 plants). This one is working with 60% of Nominal Charge.

T3: This one has a capacity of 3*75 Kva.

Places that it feed: Faculty of Electrical and Computer Engineering (FEC) Building (FEC)

Administration Module and Enviroment Engeeniering Module.

This one is working with 75% of Nominal Charge.

T4: This one has a capacity of 3*100 Kva.

Places that it feed: 03 building-Computation Faculty ( 2 Plants and Basement), 08 Building Top Management, Clothes room, Bar and Swimming Pool Bar, Kitchen, Dinning Room, and others.

In this sector we have the emergency electrical plant with capacity of 150Kva, it is a manually plant and it feed totally the 03 building, 08 building only at the top management, telephonic plant.

This one is working with 65% of Nominal Charge.

T5: This is a monophasic transformer of 10 Kva.

Places that if feeds: Students Houses and the peripheric ilumination.

This one is working with 40% of Nominal Charge.

T5: This is a monophasic transformer of 37.5 Kva.

Places that if feeds: Building of specially degree UNI.

This one is working with 48% of Nominal Charge.

The energetic system has problem of estability in the level of tension, the continuity of this service is o.k., this system is not usually out of service.

According to the percentage before indicated, it is obvious that most of the transformers bankers are able to suministrate more charge.

The information of the energetic system from the pedro arauz campus is described in annex D.

ICT resources available outside the university

The following questions are related to ICT resources (expertise, services) which may be available outside the university but within the country.

 

> Up

2.7 Are there one or more Internet Service Providers in the country? If so, please mentioned their names, location and - if possible - the maximum bandwidth the ISP can provide:

  • Company: TELEMATIX, located in Managua. Maximum bandwidth 512 Kbps
  • Company: IBW, located in Managua, Maximum bandwidth 512 Kbps
  • Company: IDEAY, located in Managua, Maximum bandwidth 512 Kbps
  • Company: NICANET, located in Managua. Maximum bandwidth 512 Kbps
  • Company: TERANET, located in Managua. Maximum bandwidth 512 Kbps
  • Company: ALFANUMERIC, located in Managua. Maximum bandwidth 512 Kbps

(Most of the companies are ofering 512 Kbps as a maximum bandwidth, but including their traffic from other clients. In case of 512 Kbps only for Universities such bandwidth should be contracted explicitly, forcing the ISP to increase the total bandwidth available)

2.8 Does one of the ISPs offer VSAT-services (access to the Internet through a satellite ground station). If the answer is yes, please mentioned the name, address, telephone, fax and e-mail address of the ISP (if available):

· Company: TELEMATIX, located in Managua. Maximum bandwidth 512 Kbps

Phone: (505) 2783131

Fax: (505) 2786328

Email: acliente@tmx.com.ni

 

· Company: IBW, located in Managua, Maximum bandwidth 512 Kbps

Phone: (505) 2786328

Fax: (505) 2785763

Email: info@ibw.com.ni

 

· Company: IDEAY, located in Managua, Maximum bandwidth 512 Kbps

Phone: (505) 2774000

Fax: (505) 2774411

Email: zambrana@ideay.net.ni

 

· Company: NICANET, located in Managua. Maximum bandwidth 512 Kbps

Phone: (505) 2785528

Fax: (505) 2787898

Email: pacm@datatex.com.ni

 

· Company: TERANET, located in Managua. Maximum bandwidth 512 Kbps

Phone: (505) 2788000

Fax: (505) 2780041

Email: lcasco@teranet.com.ni

 

· Company: ALFANUMERIC, located in Managua. Maximum bandwidth 512 Kbps

Phone: (505) 2783200

Fax: (505) 2786328

Email: www.alfanumeric.com.ni

 

> Up

2.9 Are there any companies active in Nicaragua who could possibly be contracted for the installation of wireless communication networks. If the answer is yes: please give the name/address details (if available):

· Company: TECNOSOLUCIONES, located in Managua.

Phone: (505) 2705125

Fax: (505) 2705126

Email: tecnosol@tmx.com.ni

· Company: MERINCO, located in Managua.

Phone: (505) 2651166

Fax: (505) 2650818

Email: webmaster@merinco.com.ni

· Company: IBW, located in Managua, Maximum bandwidth 512 Kbps

Phone: (505) 2786328

Fax: (505) 2785763

Email: info@ibw.com.ni

· Company: IDEAY, located in Managua, Maximum bandwidth 512 Kbps

Phone: (505) 2774000

Fax: (505) 2774411

Email: zambrana@ideay.net.ni

· Company: NICANET, located in Managua. Maximum bandwidth 512 Kbps

Phone: (505) 2785528

Fax: (505) 2787898

Email: pacm@datatex.com.ni

2.10 Are there any companies active in Nicaragua who could possibly be contracted for installation of optical fibre networks. If the answer is yes: please give the name/address details (if available):

· Company: TECNOSOLUCIONES, located in Managua.

Phone: (505) 2705125

Fax: (505) 2705126

Email: tecnosol@tmx.com.ni

· Company: MERINCO, located in Managua.

Phone: (505) 2651166

Fax: (505) 2650818

Email: webmaster@merinco.com.ni

· Company: IBW, located in Managua.

Phone: (505) 2786328

Fax: (505) 2785763

Email: info@ibw.com.ni

· Company: IDEAY, located in Managua.

Phone: (505) 2774000

Fax: (505) 2774411

Email: zambrana@ideay.net.ni

· Company: NICANET, located in Managua.

Phone: (505) 2785528

Fax: (505) 2787898

Email: pacm@datatex.com.ni

· Company: MICROSA, located in Managua.

Phone: (505) 2668915

Fax: (505) 2668916

Email: microsa@ibw.com.ni

2.11 Are there any companies active in Nicaragua who could possibly be contracted for LAN cabling networks. If the answer is yes: please give the name/address details (if available):

· Company: TECNOSOLUCIONES, located in Managua.

Phone: (505) 2705125

Fax: (505) 2705126

Email: tecnosol@tmx.com.ni

 

· Company: MERINCO, located in Managua.

Phone: (505) 2651166

Fax: (505) 2650818

Email: webmaster@merinco.com.ni

 

· Company: IBW, located in Managua.

Phone: (505) 2786328

Fax: (505) 2785763

Email: info@ibw.com.ni

 

· Company: IDEAY, located in Managua.

Phone: (505) 2774000

Fax: (505) 2774411

Email: zambrana@ideay.net.ni

 

· Company: NICANET, located in Managua.

Phone: (505) 2785528

Fax: (505) 2787898

Email: pacm@datatex.com.ni

 

· Company: MICROSA, located in Managua.

Phone: (505) 2668915

Fax: (505) 2668916

Email: microsa@ibw.com.ni

 

> Up

2.12 Are there any companies active in Nicaragua who could possibly be contracted for delivering and installation of Internet/e-mail server systems, including provision of staff training. If the answer is yes: please give the name/address details (if available):

· Company: TECNOSOLUCIONES, located in Managua.

Phone: (505) 2705125

Fax: (505) 2705126

Email: tecnosol@tmx.com.ni

· Company: MERINCO, located in Managua.

Phone: (505) 2651166

Fax: (505) 2650818

Email: webmaster@merinco.com.ni

· Company: IBW, located in Managua.

Phone: (505) 2786328

Fax: (505) 2785763

Email: info@ibw.com.ni

· Company: IDEAY, located in Managua.

Phone: (505) 2774000

Fax: (505) 2774411

Email: zambrana@ideay.net.ni

· Company: NICANET, located in Managua.

Phone: (505) 2785528

Fax: (505) 2787898

Email: pacm@datatex.com.ni

· Company: MICROSA, located in Managua.

Phone: (505) 2668915

Fax: (505) 2668916

Email: microsa@ibw.com.ni

3. Plans for building ICT Infrastructure

3.1 Are there any plans (proposals, technical designs, other) for building an ICT infrastructure spanning the whole (or parts of the) university? If the answer is yes, can these plans be made available to the consultants?

Future plans for connectivity at "Simon Bolivar" Campus

See or Download the diagram

<End of Part C>

> Up

Next Page


Download this Document in PDF format
Dont have Reader?

© Copyright Proyecto TIC Nicaragua 2001-2002
Design: Luis E. Palma
SIDA - SAREC Site Universidad Nacional de Ingenieria Universidad Nacional Autonoma de  Nicaragua - Managua Universidad Nacional Agraria Universidad Nacional Autonoma de  Nicaragua - Managu