QUICK
SCAN SURVEY
PART C: INVENTORY EXISTING ICT INFRASTRUCTURE
Developing
Information and Communication Technology (ICT)
services for institutes of higher education and research.
QUESTIONNAIRE
January 2000
General Information
Universidad
Nacional Autónoma de Nicaragua. (UNAN-M)
1. Description
of existing networking facilities
1.1 Inter-campus
networking
Describe in
brief inter-campus networking facilities (if any) by specifying
data communication links between campuses (or universitys
main compound) and individual buildings outside the campuses (or
main compound). Please specify for each link the points (buildings)
connected by the link, the distance the link is bridging, the technology
used and the capacity of the link.
If possible,
include a schematic drawing!
We do not
have.
1.2 Campus networks
Describe in
brief the networks available (if any) at the various campuses facilities
providing data communication connectivity to the individual buildings.
Do not include the description of LANs at the individual buildings!
Please specify buildings connected, distances, the technology used
and capacities. If possible, include a schematic drawing!
128 kbps wire
communication (dedicated line) link the library and the server
(IBW building, outside the University), the distance between connected
building is 2.5 kms.
64 Kbps wire
communications (coax cable) link between e-mail and internet server
at the library building and the computers lab (20 computers for
internet service to the students and teachers) the distance between
connected buildings: 350 mts.
128 kbps wire
communication (dedicated line) link betwwen Health Master Building
and his own computer lab (20 computers) for e-mail and internet
service to students and teachers: distance of the dedicated line
between Health Master Building and the server (IBW building, outside
the University) is 2.5 kms.
1.3 LANs at the individual buildings
Describe in
brief the Local Area Networks installed (if any) at the various
buildings. Please specify the number of connection points, capacities
and technology used.
Facultad de
Ciencias:
a. 10 Mbps
UTP LAN 31 connections (Lab 1 Pentium MMX)
b. 10 Mbps
UTP LAN 22 connections (Lab 2 80386)
c. 10 Mbps
UTP LAN 4 connections (Teacher´s room)
Facultad de
Ciencias de la Educación y Humanidades:
a. 10 Mbps
UTP LAN 10 connections (lab 3 Pentium 200 Mhz)
b. 10 Mbps
UTP LAN 20 connections (lab 4 80486)
c. 10 Mbps
UTP LAN 20 connections (lab 5 Pentium 133 Mhz)
Centro de
Cómputo:
a. 10 Mbps
Coax LAN 9 connections
Biblioteca:
a. 10 Mbps
UTP LAN 7 connections
Programa de
Maestría en salud Sexual y Reproductiva:
a. 10 Mbps
UTP LAN 20 connections ( Pentium )
1.4 Connection
to Internet/e-mail
Describe in
brief the links (if any) the university does have to the Internet.
Please specify the set-up, capacities and technology used.
The university
does have various link to local internet service providers (ISP),
but these are all links between individual departments and faculties
and the ISP´s, we do not have a common internet facility
serving all. Specification of the individual links:
Programa de
Salud Sexual y Reproductiva: dedicated line to ISP IBW.
Biblioteca:
dedicated line to ISP IBW.
Centro de
Cómputo: dial up to the library
Facultad de
Ciencias de la Educación y Humanidades : dial up to the
library
Facultad de
Ciencias : dial up to the libray.
Centro de
Documentación (REDUC): dial up to telematix
Acedemics
departments : dial up to the library
1.5 Internet/e-mail
facilities for common use
Does the university
have central Internet/e-mail facilities serving the various faculties,
departments, etc? If the answer is yes, please specify briefly the
configuration of the facilities, the location of the facilities
and name the group responsible for operations and maintenance
The university
does have internet facilities located at the Library building
at the main campus exist a group of persons responsible for operation
and maintenance the configuration consist of a e-mail server,
a domain name server, a proxy server, using LINUX operating systems
(all Intel computers running windows NT/ windows 95/98) and a
dial up modem bank (16 ports) the facilities can be accessed both
from the main campus and from outside the campus.
> Up
2. Other ICT
resources
2.1 Describe
briefly the major computerized information systems in use at your
university. Please indicate the number (estimate) of end-users for
each particular administration and if possible, the department considered
the main user.
¨ A computerized
financial Information System (5 years old), in use by the central
financial administration. Estimated number of users of the system
12 persons.
¨ A computerized
student´s grade control system in use by the computer center.
Estimated numbers of user of the system 5 persons.
¨ Office
automation programs such as MS office, in use by almost all faculties,
departments, etc.
2.2 What is
the number of PCs in use within the administration (estimate):
The number
of PC´s in use within the administration is estimated in:
150
2.3 What is
the number of PCs in use at the central library (estimate):
The number
of PC´s in use at the central Library is : 10
2.4 What is
the number of PCs in use at for education and research (estimate):
If possible,
give estimates for each faculty, institute, school, other.
Total number(estimated)
: 457
1. Facultad
de Ciencias de la Educación y Humanidades : 100 PC
2. Facultad
de Ciencias Médicas : 20 PC
3. Facultad
de Ciencias : 120 PC
4. Facultad
de Ciencias Económicas : 60 PC
5. Centro
de Investigaciones Geocientíficas : 5 PC
6. Centro
de Investigaciones en Recursos Acuáticos : 10 PC
7. Centro
de Investigaciones y Estudios de la Salud : 25 PC
8. Instituto
de Investigaciones Económicas y Sociales : 5 PC
9. Centro
de Investigaciones Económicas y tecnológicas : 4
PC
10. Centro
de Investigaciones Socio Educativas : 2 PC
11. Instituto
Politécnico de la Salud : 15 PC
12. Centro
Universitario Regional de Carazo : 31 PC
13. Centro
Universitario Regional de Chontales : 25 PC
14. Centro
Universitario Regional de Matagalpa : 15 PC
15. Centro
Universitario Regional de Estelí : 20 PC
2.5 Please indicate
the average condition of the present available PCs.
Approximately
75 % of total number of PC´s is older than 2 years, 35 %
of the total number consist of Intel 486 and Intel 586.
2.6 Please describe
in brief the condition of the electricity supply system at your
university:
Electricity
supply is not very reliable, we are facing power supply up and
down frequently.
3. ICT resources
available outside the university
The following
questions are related to ICT resources (expertise, services) which
may be available outside the university but within the country.
3.1 Are there
one or more Internet Service Providers in the country? If so, please
mentioned their names, location and - if possible - the maximum
bandwidth the ISP can provide:
· Company:
TELEMATIX, located in Managua. Maximum bandwidth 512 Kbps
· Company:
IBW, located in Managua, Maximum bandwidth 512 Kbps
· Company:
IDEAY, located in Managua, Maximum bandwidth 512 Kbps
· Company:
NICANET, located in Managua. Maximum bandwidth 512 Kbps
· Company:
TERANET, located in Managua. Maximum bandwidth 512 Kbps
· Company:
ALFANUMERIC, located in Managua. Maximum bandwidth 512 Kbps
(Most of the
companies are ofering 512 Kbps as a maximum bandwidth, but including
their traffic from other clients. In case of 512 Kbps only for
Universities such bandwidth should be contracted explicitly, forcing
the ISP to increase the total bandwidth available)
> Up
3.2 Does one
of the ISPs offer VSAT-services (access to the Internet through
a satellite ground station). If the answer is yes, please mentioned
the name, address, telephone, fax and e-mail address of the ISP
(if available):
· Company:
TELEMATIX, located in Managua. Maximum bandwidth 512 Kbps
Phone: (505)
2783131
Fax: (505)
2786328
Email: acliente@tmx.com.ni
· Company:
IBW, located in Managua, Maximum bandwidth 512 Kbps
Phone: (505)
2786328
Fax: (505)
2785763
Email: info@ibw.com.ni
· Company:
IDEAY, located in Managua, Maximum bandwidth 512 Kbps
Phone: (505)
2774000
Fax: (505)
2774411
Email: zambrana@ideay.net.ni
· Company:
NICANET, located in Managua. Maximum bandwidth 512 Kbps
Phone: (505)
2785528
Fax: (505)
2787898
Email: pacm@datatex.com.ni
· Company:
TERANET, located in Managua. Maximum bandwidth 512 Kbps
Phone: (505)
2788000
Fax: (505)
2780041
Email: lcasco@teranet.com.ni
· Company:
ALFANUMERIC, located in Managua. Maximum bandwidth 512 Kbps
Phone: (505)
2783200
Fax: (505)
2786328
Email: www.alfanumeric.com.ni
3.3 Are there
any companies active in Nicaragua who could possibly be contracted
for the installation of wireless communication networks. If the
answer is yes: please give the name/address details (if available):
· Company:
TECNOSOLUCIONES, located in Managua.
Phone: (505)
2705125
Fax: (505)
2705126
Email: tecnosol@tmx.com.ni
· Company:
MERINCO, located in Managua.
Phone: (505)
2651166
Fax: (505)
2650818
Email: webmaster@merinco.com.ni
· Company:
IBW, located in Managua.
Phone: (505)
2786328
Fax: (505)
2785763
Email: info@ibw.com.ni
· Company:
IDEAY, located in Managua,
Phone: (505)
2774000
Fax: (505)
2774411
Email: zambrana@ideay.net.ni
· Company:
NICANET, located in Managua.
Phone: (505)
2785528
Fax: (505)
2787898
Email: pacm@datatex.com.ni
> Up
3.4 Are there
any companies active in Nicaragua who could possibly be contracted
for installation of optical fibre networks. If the answer is yes:
please give the name/address details (if available):
· Company:
TECNOSOLUCIONES, located in Managua.
Phone: (505)
2705125
Fax: (505)
2705126
Email: tecnosol@tmx.com.ni
· Company:
MERINCO, located in Managua.
Phone: (505)
2651166
Fax: (505)
2650818
Email: webmaster@merinco.com.ni
· Company:
IBW, located in Managua, Maximum bandwidth 512 Kbps
Phone: (505)
2786328
Fax: (505)
2785763
Email: info@ibw.com.ni
· Company:
IDEAY, located in Managua, Maximum bandwidth 512 Kbps
Phone: (505)
2774000
Fax: (505)
2774411
Email: zambrana@ideay.net.ni
· Company:
NICANET, located in Managua. Maximum bandwidth 512 Kbps
Phone: (505)
2785528
Fax: (505)
2787898
Email: pacm@datatex.com.ni
· Company:
MICROSA, located in Managua.
Phone: (505)
2668915
Fax: (505)
2668916
Email: microsa@ibw.com.ni
3.5 Are there
any companies active in Nicaragua who could possibly be contracted
for LAN cabling networks. If the answer is yes: please give the
name/address details (if available):
· Company:
TECNOSOLUCIONES, located in Managua.
Phone: (505)
2705125
Fax: (505)
2705126
Email: tecnosol@tmx.com.ni
· Company:
MERINCO, located in Managua.
Phone: (505)
2651166
Fax: (505)
2650818
Email: webmaster@merinco.com.ni
· Company:
IBW, located in Managua.
Phone: (505)
2786328
Fax: (505)
2785763
Email: info@ibw.com.ni
· Company:
IDEAY, located in Managua.
Phone: (505)
2774000
Fax: (505)
2774411
Email: zambrana@ideay.net.ni
· Company:
NICANET, located in Managua.
Phone: (505)
2785528
Fax: (505)
2787898
Email: pacm@datatex.com.ni
· Company:
MICROSA, located in Managua.
Phone: (505)
2668915
Fax: (505)
2668916
Email: microsa@ibw.com.ni
> Up
3.6 Are there
any companies active in Nicaragua who could possibly be contracted
for delivering and installation of Internet/e-mail server systems,
including provision of staff training. If the answer is yes: please
give the name/address details (if available):
· Company:
TECNOSOLUCIONES, located in Managua.
Phone: (505)
2705125
Fax: (505)
2705126
Email: tecnosol@tmx.com.ni
· Company:
MERINCO, located in Managua.
Phone: (505)
2651166
Fax: (505)
2650818
Email: webmaster@merinco.com.ni
· Company:
IBW, located in Managua.
Phone: (505)
2786328
Fax: (505)
2785763
Email: info@ibw.com.ni
· Company:
IDEAY, located in Managua.
Phone: (505)
2774000
Fax: (505)
2774411
Email: zambrana@ideay.net.ni
· Company:
NICANET, located in Managua.
Phone: (505)
2785528
Fax: (505)
2787898
Email: pacm@datatex.com.ni
· Company:
MICROSA, located in Managua.
Phone: (505)
2668915
Fax: (505)
2668916
Email: microsa@ibw.com.ni
4. Plans for
building ICT Infrastructure
4.1 Are there
any plans (proposals, technical designs, other) for building an
ICT infrastructure spanning the whole (or parts of the) university?
If the answer is yes, can these plans be made available to the consultants?
<End of Part
C>
> Up
Next
Page 
|